Icare IC100

Icare IC100

Excellent

Icare®’s patented rebound technology is a proven technique for obtaining accurate and rapid IOP measurements from all your patients. Measuring requires no anesthesia, drops, air puffs or other preparation. The Icare® ic200 tonometer takes reliable measurements with wide flexibility in positioning. An intuitive user interface maximizes clinical efficiency even in the most demanding situations.

  • Easy Setup
  • 24/7 VIP Support
View full details

Technical Specifications

Rebound Measurement

Utilizes iCare’s patented rebound technology, where a small disposable probe lightly contacts the cornea to measure IOP—no anesthetic drops, air puffs, or calibration needed.

Automatic Measuring Sequence (AMS)

Supports single-measurement mode or rapid six-series mode with one-button operation, enabling fast and repeatable readings.

EasyNav & EasyPos Guidance

Integrated OLED display guides operator through alignment; probe-base LEDs indicate correct positioning with green light.

Ultra-Light and Portable

Device dimensions approx. 29 × 95 × 215 mm; weight around 135 g without batteries (~230 g with four AA batteries). Ideal for mobile exams.

Performance & Accuracy

Measurement Range

IOP range from 7 to 50 mmHg.

Accuracy & Repeatability

± 1.2 mmHg for readings ≤ 20 mmHg, ± 2.2 mmHg for readings > 20 mmHg

Coefficient of variation ≤ 8 % for repeated measures

Performance matches Goldmann applanation tonometry within clinically acceptable limits.

Power, Display & Interface

Power Supply

Four non‑rechargeable AA batteries (alkaline LR6, 1.5 V). Device automatically powers off after ~3 minutes of inactivity.

Display Interface

Bright OLED display shows measurement modes, results, language options, rapid status, and error messages. Multilingual menu support.

Maintenance-Free Design

No calibration required; probes are disposable and single-use to prevent cross-contamination.

Why It Matters

Because it’s fast, painless, and portable, the iCare IC100 empowers clinicians to deliver efficient IOP monitoring without compromising patient comfort or accuracy. Its ease of use and minimal training requirements make it a staple for high-throughput screening and pediatric ophthalmic care

iCare IC100 – Product Overview


The iCare IC100 is a compact and highly portable rebound tonometer designed for accurate and gentle intraocular pressure (IOP) measurement in both standing and seated patients. It’s a go-to device for glaucoma screening and routine IOP checks in clinics, hospitals, and even optical shops. Its wireless, lightweight design allows use anywhere with just four AA batteries.